Show Hamamatsu Avalanche Photo Diode 2405026293 - Archived data from Wed, 12. June 2019 15:02:27 CEST
This is all the information about APD 2405026293. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2405026293 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C10 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.1 V |
Dark current: | 5.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 9 |
Position in Box: | 39 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 12. Nov 2018 |
Sent for analysis after irradiation: | 13. Dec 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 07. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:48:57 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:15:05 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:21:16 CEST | jreher | Updated APD characteristics via API. |
25. Jun 2020 11:26:02 CEST | jreher | Assigned to capsule by script |
20. Feb 2020 13:34:34 CET | jreher | Updated box and position via API. |
27. Nov 2019 19:30:59 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:11:37 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:06:03 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:46:06 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:31:00 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:02:27 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:12:51 CET | Tobias | Corrected dark current unit. |
13. Dec 2018 14:03:54 CET | markus.moritz | |
23. Nov 2018 11:58:51 CET | markus.moritz | |
12. Jan 2018 13:16:51 CET | Tobias | Imported from Hamamatsu datasheet. |