RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026196 - Archived data from Wed, 03. February 2021 18:14:55 CET


This is all the information about APD 2404026196. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026196
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.3 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 8
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 12. Nov 2018
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.5646775 V     T = -25 °C: 349.8588746 V
Voltage for Gain 150: T = +20 °C: 393.4693991 V     T = -25 °C: 357.3220656 V
Voltage for Gain 200: T = +20 °C: 397.8617197 V     T = -25 °C: 361.5114344 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.445712732 V-1     T = -25 °C: 4.969243948 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.67849987 V-1     T = -25 °C: 9.260537341 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.2352251 V-1     T = -25 °C: 14.64927761 V-1
Break-through voltage: T = +20 °C: 413.0627808 V     T = -25 °C: 376.5988112 V
   
Notes:


Version history

Time Author Change comment
29. Apr 2021 17:02:53 CEST oafedulidis Assigned to capsule by script
16. Feb 2021 12:26:23 CET jreher Updated box and position via API.
05. Feb 2021 10:48:43 CET jreher Updated box and position via API.
03. Feb 2021 18:14:55 CET jreher Updated box and position via API.
11. Aug 2020 17:21:01 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:47 CET jreher Updated APD location via API.
25. Nov 2019 17:11:31 CET jreher Updated box and position via API.
04. Jul 2019 11:05:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:59 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:54 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:53 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:49 CET Tobias Corrected dark current unit.
26. Nov 2018 12:19:06 CET markus.moritz
26. Nov 2018 11:26:23 CET markus.moritz
16. Nov 2018 11:55:38 CET markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.