RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026170 - Archived data from Tue, 11. August 2020 17:20:54 CEST


This is all the information about APD 2404026170. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026170
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.1 V
Dark current: 3.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 7
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.1552586 V     T = -25 °C: 344.2296242 V
Voltage for Gain 150: T = +20 °C: 386.9875203 V     T = -25 °C: 351.5996142 V
Voltage for Gain 200: T = +20 °C: 391.3701256 V     T = -25 °C: 355.7271552 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.615438372 V-1     T = -25 °C: 4.870065061 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.072133153 V-1     T = -25 °C: 9.011922944 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.03793132 V-1     T = -25 °C: 16.02418361 V-1
Break-through voltage: T = +20 °C: 407.4305478 V     T = -25 °C: 371.4139764 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:36 CET jreher Updated box and position via API.
03. Feb 2021 18:14:49 CET jreher Updated box and position via API.
08. Dec 2020 17:11:03 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:51 CEST jreher Updated box and position via API.
11. Aug 2020 17:20:54 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:38 CET jreher Updated APD location via API.
25. Nov 2019 17:11:28 CET jreher Updated box and position via API.
04. Jul 2019 11:05:47 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:56 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:51 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:12 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:48 CET Tobias Corrected dark current unit.
02. Oct 2018 13:54:49 CEST markus.moritz
12. Jan 2018 13:16:49 CET Tobias Imported from Hamamatsu datasheet.