RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2404026156 - Archived data from Fri, 05. February 2021 10:48:33 CET


This is all the information about APD 2404026156. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2404026156
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B08
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 255
Position in Box: 37
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.3298808 V     T = -25 °C: 351.4731581 V
Voltage for Gain 150: T = +20 °C: 395.2520398 V     T = -25 °C: 358.9614799 V
Voltage for Gain 200: T = +20 °C: 399.6185133 V     T = -25 °C: 363.1866027 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.441433221 V-1     T = -25 °C: 4.710185529 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.441970167 V-1     T = -25 °C: 9.311437651 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.09533571 V-1     T = -25 °C: 14.50682045 V-1
Break-through voltage: T = +20 °C: 414.6822181 V     T = -25 °C: 378.4247353 V
   
Notes:


Version history

Time Author Change comment
26. Apr 2021 15:21:17 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:33 CET jreher Updated box and position via API.
03. Feb 2021 18:14:48 CET jreher Updated box and position via API.
11. Aug 2020 17:20:55 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:37 CET jreher Updated APD location via API.
25. Nov 2019 17:11:27 CET jreher Updated box and position via API.
04. Jul 2019 11:05:46 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:56 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:51 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:19 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:48 CET Tobias Corrected dark current unit.
02. Oct 2018 14:07:20 CEST markus.moritz
26. Sep 2018 11:55:06 CEST markus.moritz
12. Jan 2018 13:16:48 CET Tobias Imported from Hamamatsu datasheet.