RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2403026132 - Archived data from Wed, 16. June 2021 16:03:44 CEST


This is all the information about APD 2403026132. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2403026132
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C04
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 386.2 V
Dark current: 7.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 255
Position in Box: 36
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.7182974 V     T = -25 °C: 350.100223 V
Voltage for Gain 150: T = +20 °C: 393.532404 V     T = -25 °C: 357.5743326 V
Voltage for Gain 200: T = +20 °C: 397.866546 V     T = -25 °C: 361.7658373 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.440398141 V-1     T = -25 °C: 4.866862752 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.740138454 V-1     T = -25 °C: 9.043135593 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.44446181 V-1     T = -25 °C: 16.10656624 V-1
Break-through voltage: T = +20 °C: 412.9284393 V     T = -25 °C: 377.0280029 V
   
Notes:


Version history

Time Author Change comment
11. Jul 2022 14:25:48 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:03:44 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:00:01 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:52:42 CEST oafedulidis Updated box and position via API.
26. Apr 2021 15:21:16 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:30 CET jreher Updated box and position via API.
03. Feb 2021 18:14:46 CET jreher Updated box and position via API.
11. Aug 2020 17:20:52 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:36 CET jreher Updated APD location via API.
25. Nov 2019 17:11:26 CET jreher Updated box and position via API.
04. Jul 2019 11:05:45 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:55 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:50 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:11 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:47 CET Tobias Corrected dark current unit.
02. Oct 2018 14:37:25 CEST markus.moritz
26. Sep 2018 11:49:48 CEST markus.moritz
12. Jan 2018 13:16:48 CET Tobias Imported from Hamamatsu datasheet.