Subdetector specification:  
Serial: 2403026075
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D09
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.3 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 36
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.6271414 V     T = -25 °C: 344.9789496 V
Voltage for Gain 150: T = +20 °C: 388.3673733 V     T = -25 °C: 352.3154221 V
Voltage for Gain 200: T = +20 °C: 392.6792134 V     T = -25 °C: 356.4265142 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.475431494 V-1     T = -25 °C: 4.971132366 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.790148518 V-1     T = -25 °C: 9.322846558 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.47027903 V-1     T = -25 °C: 14.77948287 V-1
Break-through voltage: T = +20 °C: 408.2254124 V     T = -25 °C: 371.8080731 V
   
Notes: foam


Version history

Time Author Change comment
26. Oct 2021 15:06:30 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:20:41 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:28:34 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:30 CET jreher Updated box and position via API.
03. Feb 2021 18:14:00 CET jreher Updated box and position via API.
11. Aug 2020 17:19:54 CEST jreher Updated APD characteristics via API.
11. Aug 2020 16:51:28 CEST jreher Updated APD characteristics via API.
11. Aug 2020 16:42:14 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:28:38 CET jreher Updated APD location via API.
25. Nov 2019 17:10:54 CET jreher Updated box and position via API.
25. Nov 2019 16:56:02 CET jreher Updated box and position via API.
03. Jul 2019 20:03:15 CEST jreher Updated APD location via API.
13. Jun 2019 11:23:38 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 17:13:11 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:45:27 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:22 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:02 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:54:10 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:45 CET Tobias Corrected dark current unit.
21. Aug 2018 09:04:22 CEST markus.moritz
20. Aug 2018 14:09:23 CEST markus.moritz
12. Jan 2018 13:16:47 CET Tobias Imported from Hamamatsu datasheet.