RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2402026048 - Archived data from Mon, 10. May 2021 14:00:59 CEST


This is all the information about APD 2402026048. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2402026048
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A08
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 5.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 175
Position in Box: 50
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.7869936 V     T = -25 °C: 352.0209084 V
Voltage for Gain 150: T = +20 °C: 395.6362647 V     T = -25 °C: 359.526537 V
Voltage for Gain 200: T = +20 °C: 399.9843628 V     T = -25 °C: 363.7234121 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.697106603 V-1     T = -25 °C: 4.867182484 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.533323676 V-1     T = -25 °C: 8.938793226 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.81820415 V-1     T = -25 °C: 15.82149218 V-1
Break-through voltage: T = +20 °C: 413.836298 V     T = -25 °C: 377.9820101 V
   
Notes: foam


Version history

Time Author Change comment
16. Nov 2021 09:35:25 CET oafedulidis Assigned to capsule by script
10. May 2021 14:00:59 CEST oafedulidis Updated box and position via API.
26. Apr 2021 14:30:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:59 CET jreher Updated box and position via API.
03. Feb 2021 18:14:19 CET jreher Updated box and position via API.
11. Aug 2020 17:20:19 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:29:55 CET jreher Updated APD location via API.
25. Nov 2019 17:11:10 CET jreher Updated box and position via API.
04. Jul 2019 11:04:31 CEST jreher Updated APD location via API.
04. Jul 2019 11:04:21 CEST jreher Updated APD location via API.
04. Jul 2019 11:03:01 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:27 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:16 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:34 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:56 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:45 CET Tobias Corrected dark current unit.
21. Aug 2018 09:02:43 CEST markus.moritz
20. Aug 2018 13:50:07 CEST markus.moritz
12. Jan 2018 13:16:47 CET Tobias Imported from Hamamatsu datasheet.