RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2402026046 - Archived data from Fri, 12. January 2018 13:16:47 CET


This is all the information about APD 2402026046. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2402026046
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.3 V
Dark current: 5.1E-9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 3
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:47:59 CET jreher Updated box and position via API.
03. Feb 2021 18:14:19 CET jreher Updated box and position via API.
11. Aug 2020 17:20:19 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:59:30 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:19 CET jreher Updated box and position via API.
27. Nov 2019 19:29:54 CET jreher Updated APD location via API.
25. Nov 2019 17:11:09 CET jreher Updated box and position via API.
04. Jul 2019 11:04:31 CEST jreher Updated APD location via API.
04. Jul 2019 11:04:21 CEST jreher Updated APD location via API.
04. Jul 2019 11:03:01 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:27 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:16 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:34 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:56 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:45 CET Tobias Corrected dark current unit.
21. Aug 2018 09:02:27 CEST markus.moritz
20. Aug 2018 13:51:34 CEST markus.moritz
12. Jan 2018 13:16:47 CET Tobias Imported from Hamamatsu datasheet.