Subdetector specification:  
Serial: 2402026039
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 175
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.8282029 V     T = -25 °C: 349.9488939 V
Voltage for Gain 150: T = +20 °C: 393.6961828 V     T = -25 °C: 357.4772365 V
Voltage for Gain 200: T = +20 °C: 398.0807345 V     T = -25 °C: 361.694165 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.676396534 V-1     T = -25 °C: 4.862464758 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.214002952 V-1     T = -25 °C: 8.917824759 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.35292111 V-1     T = -25 °C: 15.60676379 V-1
Break-through voltage: T = +20 °C: 412.7210414 V     T = -25 °C: 376.633142 V
   
Notes: foam


Version history

Time Author Change comment
26. Apr 2021 14:30:39 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:47:58 CET jreher Updated box and position via API.
03. Feb 2021 18:14:18 CET jreher Updated box and position via API.
11. Aug 2020 17:20:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:29:54 CET jreher Updated APD location via API.
25. Nov 2019 17:11:09 CET jreher Updated box and position via API.
04. Jul 2019 11:04:30 CEST jreher Updated APD location via API.
04. Jul 2019 11:04:20 CEST jreher Updated APD location via API.
04. Jul 2019 11:03:00 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:26 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:15 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:38 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:34 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:56 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:45 CET Tobias Corrected dark current unit.
21. Aug 2018 09:00:37 CEST markus.moritz
20. Aug 2018 13:48:44 CEST markus.moritz
12. Jan 2018 13:16:47 CET Tobias Imported from Hamamatsu datasheet.