RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2402026025 - Archived data from Wed, 03. February 2021 18:14:17 CET


This is all the information about APD 2402026025. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2402026025
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2402026025/2505027953
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377.5 V
Dark current: 4 nA
   
Screening Logistics:  
Available: No
Storage Box: 3
Position in Box: 28
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.3172459 V     T = -25 °C: 342.253656 V
Voltage for Gain 150: T = +20 °C: 385.1127331 V     T = -25 °C: 349.5967121 V
Voltage for Gain 200: T = +20 °C: 389.4673023 V     T = -25 °C: 353.7090329 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.587535339 V-1     T = -25 °C: 4.912378051 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.984635554 V-1     T = -25 °C: 9.039202888 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.98139849 V-1     T = -25 °C: 16.16577628 V-1
Break-through voltage: T = +20 °C: 405.384099 V     T = -25 °C: 369.3172785 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:47:57 CET jreher Updated box and position via API.
03. Feb 2021 18:14:17 CET jreher Updated box and position via API.
11. Aug 2020 17:20:15 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:35 CEST jreher Assigned to capsule by script
13. Feb 2020 14:24:01 CET jreher Updated box and position via API.
27. Nov 2019 19:29:53 CET jreher Updated APD location via API.
25. Nov 2019 17:11:07 CET jreher Updated box and position via API.
04. Jul 2019 11:04:29 CEST jreher Updated APD location via API.
04. Jul 2019 11:04:19 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:59 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:25 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:14 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:37 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:33 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:55 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:44 CET Tobias Corrected dark current unit.
21. Aug 2018 08:56:06 CEST markus.moritz
20. Aug 2018 13:33:37 CEST markus.moritz
12. Jan 2018 13:16:47 CET Tobias Imported from Hamamatsu datasheet.