Show Hamamatsu Avalanche Photo Diode 2402026013 - Archived data from Tue, 11. August 2020 17:20:13 CEST


This is all the information about APD 2402026013. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2402026013
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2804031070/2402026013
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: D04
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.2 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: No
Storage Box: 3
Position in Box: 17
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4096889 V     T = -25 °C: 345.0915111 V
Voltage for Gain 150: T = +20 °C: 388.2764186 V     T = -25 °C: 352.5056505 V
Voltage for Gain 200: T = +20 °C: 392.5892603 V     T = -25 °C: 356.6491455 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.038397006 V-1     T = -25 °C: 4.44712335 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.062878914 V-1     T = -25 °C: 10.55785283 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.84224409 V-1     T = -25 °C: 15.732392 V-1
Break-through voltage: T = +20 °C: 407.9133257 V     T = -25 °C: 371.8977669 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:47:56 CET jreher Updated box and position via API.
03. Feb 2021 18:14:16 CET jreher Updated box and position via API.
11. Aug 2020 17:20:13 CEST jreher Updated APD characteristics via API.
25. Jun 2020 11:21:59 CEST jreher Assigned to capsule by script
19. Feb 2020 11:53:41 CET jreher Updated box and position via API.
27. Nov 2019 19:29:52 CET jreher Updated APD location via API.
25. Nov 2019 17:11:06 CET jreher Updated box and position via API.
04. Jul 2019 11:04:28 CEST jreher Updated APD location via API.
04. Jul 2019 11:04:18 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:58 CEST jreher Updated APD location via API.
04. Jul 2019 11:02:24 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:13 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:12 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:46 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:56:14 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:44 CET Tobias Corrected dark current unit.
21. Aug 2018 08:51:22 CEST markus.moritz
20. Aug 2018 13:24:41 CEST markus.moritz
12. Jan 2018 13:16:46 CET Tobias Imported from Hamamatsu datasheet.