RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2402026012 - Archived data from Wed, 03. February 2021 18:14:15 CET


This is all the information about APD 2402026012. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2402026012
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: At GSI for QE measurement
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D02
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.6 V
Dark current: 5.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 3
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 24. Jul 2018
Sent for analysis after irradiation: 21. Aug 2018
Return for assembly: none
   
Irradiation:  
Date: 16. Aug 2018
Dose used: 30 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Aug 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.6443587 V     T = -25 °C: 347.9818746 V
Voltage for Gain 150: T = +20 °C: 391.5016029 V     T = -25 °C: 355.4765557 V
Voltage for Gain 200: T = +20 °C: 395.9370594 V     T = -25 °C: 359.6687171 V
Gain/Voltage slope at M = 100: T = +20 °C: 5.032112198 V-1     T = -25 °C: 5.055632744 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.675424921 V-1     T = -25 °C: 9.549213547 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.26323272 V-1     T = -25 °C: 14.97247191 V-1
Break-through voltage: T = +20 °C: 411.6904656 V     T = -25 °C: 375.5123066 V
   
Notes: foam


Version history

Time Author Change comment
05. Feb 2021 10:47:56 CET jreher Updated box and position via API.
03. Feb 2021 18:14:15 CET jreher Updated box and position via API.
11. Aug 2020 17:20:13 CEST jreher Updated APD characteristics via API.
28. Nov 2019 10:39:10 CET jreher Updated APD location via API.
25. Nov 2019 17:11:06 CET jreher Updated box and position via API.
13. Jun 2019 14:19:16 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:36 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:31 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:12 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:58:46 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 14:56:14 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:44 CET Tobias Corrected dark current unit.
21. Aug 2018 08:51:13 CEST markus.moritz
20. Aug 2018 13:26:01 CEST markus.moritz
12. Jan 2018 13:16:46 CET Tobias Imported from Hamamatsu datasheet.