Subdetector specification:  
Serial: 2402025992
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2402025992/2417027257
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382 V
Dark current: 7.6 nA
   
Screening Logistics:  
Available: No
Storage Box: 6
Position in Box: 47
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.1986772 V     T = -25 °C: 346.626624 V
Voltage for Gain 150: T = +20 °C: 390.1341704 V     T = -25 °C: 354.1337162 V
Voltage for Gain 200: T = +20 °C: 394.4743059 V     T = -25 °C: 358.3266441 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.535168964 V-1     T = -25 °C: 4.656482827 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.078861745 V-1     T = -25 °C: 9.441929712 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.95985854 V-1     T = -25 °C: 17.12447737 V-1
Break-through voltage: T = +20 °C: 410.1201209 V     T = -25 °C: 373.8022748 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:23 CET jreher Updated box and position via API.
03. Feb 2021 18:14:41 CET jreher Updated box and position via API.
11. Aug 2020 17:20:48 CEST jreher Updated APD characteristics via API.
27. Mar 2020 11:32:37 CET jreher Assigned to capsule by script
13. Feb 2020 15:25:41 CET jreher Updated box and position via API.
27. Nov 2019 19:30:27 CET jreher Updated APD location via API.
25. Nov 2019 17:11:24 CET jreher Updated box and position via API.
04. Jul 2019 11:05:39 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:53 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:03 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:43 CET Tobias Corrected dark current unit.
02. Oct 2018 15:36:04 CEST markus.moritz
26. Sep 2018 12:29:44 CEST markus.moritz
12. Jan 2018 13:16:46 CET Tobias Imported from Hamamatsu datasheet.