Subdetector specification:  
Serial: 2402025989
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 6.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 6
Position in Box: 44
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: 02. Oct 2018
Return for assembly: none
   
Irradiation:  
Date: 27. Sep 2018
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 28. Sep 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.159246 V     T = -25 °C: 346.7491632 V
Voltage for Gain 150: T = +20 °C: 390.0586028 V     T = -25 °C: 354.1350672 V
Voltage for Gain 200: T = +20 °C: 394.4582764 V     T = -25 °C: 358.3379327 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.491479592 V-1     T = -25 °C: 5.292459926 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.454934696 V-1     T = -25 °C: 9.443508716 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.20978915 V-1     T = -25 °C: 14.41352036 V-1
Break-through voltage: T = +20 °C: 410.4259984 V     T = -25 °C: 374.025011 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 10:46:10 CET oafedulidis Assigned to capsule by script
17. May 2021 09:17:32 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:23 CET jreher Updated box and position via API.
03. Feb 2021 18:14:41 CET jreher Updated box and position via API.
11. Aug 2020 17:20:47 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:27 CET jreher Updated APD location via API.
25. Nov 2019 17:11:23 CET jreher Updated box and position via API.
04. Jul 2019 11:05:39 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:52 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:01:03 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:43 CET Tobias Corrected dark current unit.
02. Oct 2018 15:38:59 CEST markus.moritz
26. Sep 2018 12:31:09 CEST markus.moritz
12. Jan 2018 13:16:46 CET Tobias Imported from Hamamatsu datasheet.