Show Hamamatsu Avalanche Photo Diode 2402025988 - Archived data from Tue, 11. August 2020 17:20:47 CEST
This is all the information about APD 2402025988. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2402025988 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D12 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.3 V |
Dark current: | 7.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 6 |
Position in Box: | 43 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 21. Sep 2018 |
Sent for analysis after irradiation: | 02. Oct 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 27. Sep 2018 |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 28. Sep 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.5430203 V T = -25 °C: 349.8380421 V |
Voltage for Gain 150: | T = +20 °C: 393.4356284 V T = -25 °C: 357.295758 V |
Voltage for Gain 200: | T = +20 °C: 397.7972553 V T = -25 °C: 361.504897 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.311212276 V-1 T = -25 °C: 5.125431034 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.285825886 V-1 T = -25 °C: 9.302345115 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.10964622 V-1 T = -25 °C: 16.03532904 V-1 |
Break-through voltage: | T = +20 °C: 412.8086113 V T = -25 °C: 376.5950104 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
29. Apr 2021 17:02:51 CEST | oafedulidis | Assigned to capsule by script |
16. Feb 2021 12:26:23 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:48:23 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:14:41 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:20:47 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:30:27 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:11:23 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:05:39 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:45:52 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:30:48 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 15:01:03 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 00:12:43 CET | Tobias | Corrected dark current unit. |
02. Oct 2018 15:39:49 CEST | markus.moritz | |
26. Sep 2018 12:31:34 CEST | markus.moritz | |
12. Jan 2018 13:16:46 CET | Tobias | Imported from Hamamatsu datasheet. |