RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2401025926 - Archived data from Fri, 05. February 2021 10:48:15 CET


This is all the information about APD 2401025926. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2401025926
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E02
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 387.9 V
Dark current: 3.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 5
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 387.1232567 V     T = -25 °C: 351.2240998 V
Voltage for Gain 150: T = +20 °C: 394.9906008 V     T = -25 °C: 358.7668287 V
Voltage for Gain 200: T = +20 °C: 399.3560428 V     T = -25 °C: 362.9787363 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.610670528 V-1     T = -25 °C: 4.771357574 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.124444147 V-1     T = -25 °C: 9.696828328 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.26670738 V-1     T = -25 °C: 15.44690901 V-1
Break-through voltage: T = +20 °C: 414.5509177 V     T = -25 °C: 378.5840019 V
   
Notes:


Version history

Time Author Change comment
15. Apr 2021 17:00:59 CEST jreher Updated box and position via API.
05. Feb 2021 10:48:15 CET jreher Updated box and position via API.
03. Feb 2021 18:14:34 CET jreher Updated box and position via API.
11. Aug 2020 17:20:37 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:16 CET jreher Updated APD location via API.
25. Nov 2019 17:11:19 CET jreher Updated box and position via API.
04. Jul 2019 11:05:31 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:33 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:44 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:53 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:41 CET Tobias Corrected dark current unit.
26. Sep 2018 12:59:00 CEST markus.moritz
12. Jan 2018 13:16:45 CET Tobias Imported from Hamamatsu datasheet.