RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2401025917 - Archived data from Wed, 21. April 2021 14:49:15 CEST


This is all the information about APD 2401025917. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2401025917
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.2 V
Dark current: 3.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 26
Position in Box: 44
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.2773125 V     T = -25 °C: 344.9298273 V
Voltage for Gain 150: T = +20 °C: 388.1476648 V     T = -25 °C: 352.4091543 V
Voltage for Gain 200: T = +20 °C: 392.5222206 V     T = -25 °C: 356.4906852 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.144726361 V-1     T = -25 °C: 5.049964974 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.268384178 V-1     T = -25 °C: 8.720549678 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.20638675 V-1     T = -25 °C: 16.39838685 V-1
Break-through voltage: T = +20 °C: 408.5185783 V     T = -25 °C: 372.1451356 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:23:28 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 10:31:48 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:49:15 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:48:14 CET jreher Updated box and position via API.
03. Feb 2021 18:14:33 CET jreher Updated box and position via API.
11. Aug 2020 17:20:35 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:15 CET jreher Updated APD location via API.
25. Nov 2019 17:11:18 CET jreher Updated box and position via API.
04. Jul 2019 11:05:30 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:33 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:47 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:46 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:41 CET Tobias Corrected dark current unit.
26. Sep 2018 12:54:25 CEST markus.moritz
12. Jan 2018 13:16:45 CET Tobias Imported from Hamamatsu datasheet.