RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2320025866 - Archived data from Tue, 11. August 2020 17:20:29 CEST


This is all the information about APD 2320025866. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2320025866
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2320025866/2512028454
Unit: #1049 (barcode 1309011681)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: D06
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.4 V
Dark current: 6.4 nA
   
Screening Logistics:  
Available: No
Storage Box: 5
Position in Box: 1
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.4631207 V     T = -25 °C: 344.2609471 V
Voltage for Gain 150: T = +20 °C: 387.3045548 V     T = -25 °C: 351.6361257 V
Voltage for Gain 200: T = +20 °C: 391.6904214 V     T = -25 °C: 355.7657888 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.507954163 V-1     T = -25 °C: 4.85747917 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.738000824 V-1     T = -25 °C: 9.921301405 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.18945056 V-1     T = -25 °C: 15.91249579 V-1
Break-through voltage: T = +20 °C: 407.3200464 V     T = -25 °C: 370.8799768 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:09 CET jreher Updated box and position via API.
03. Feb 2021 18:14:29 CET jreher Updated box and position via API.
11. Aug 2020 17:20:29 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:46:08 CEST jreher Assigned to capsule by script
13. Feb 2020 14:23:56 CET jreher Updated box and position via API.
27. Nov 2019 19:30:13 CET jreher Updated APD location via API.
25. Nov 2019 17:11:15 CET jreher Updated box and position via API.
04. Jul 2019 11:05:28 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:30 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:44 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:02 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:40 CET Tobias Corrected dark current unit.
26. Sep 2018 12:41:13 CEST markus.moritz
12. Jan 2018 13:16:44 CET Tobias Imported from Hamamatsu datasheet.