Subdetector specification:  
Serial: 2320025861
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2401025944/2320025861
Unit: #860 (barcode 1309009435)
Preamp: 4397
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: B06
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 379.8 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: No
Storage Box: 4
Position in Box: 46
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.8029228 V     T = -25 °C: 344.8594597 V
Voltage for Gain 150: T = +20 °C: 387.6419792 V     T = -25 °C: 352.2271967 V
Voltage for Gain 200: T = +20 °C: 392.0037469 V     T = -25 °C: 356.3687792 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.382245849 V-1     T = -25 °C: 5.052643567 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.611007864 V-1     T = -25 °C: 9.489586528 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.050241 V-1     T = -25 °C: 15.06082353 V-1
Break-through voltage: T = +20 °C: 407.4709776 V     T = -25 °C: 371.472117 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:48:06 CET jreher Updated box and position via API.
03. Feb 2021 18:14:27 CET jreher Updated box and position via API.
11. Aug 2020 17:20:28 CEST jreher Updated APD characteristics via API.
13. Feb 2020 14:42:51 CET jreher Updated box and position via API.
27. Nov 2019 19:30:05 CET jreher Updated APD location via API.
25. Nov 2019 17:11:14 CET jreher Updated box and position via API.
17. Oct 2019 14:07:46 CEST tholtmann Assigned to unit by script
17. Oct 2019 13:50:55 CEST tholtmann Assigned to capsule by script
04. Jul 2019 11:05:23 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:24 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:43 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:39 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:40 CET Tobias Corrected dark current unit.
26. Sep 2018 11:25:16 CEST markus.moritz
12. Jan 2018 13:16:44 CET Tobias Imported from Hamamatsu datasheet.