RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2320025848 - Archived data from Tue, 11. August 2020 17:20:26 CEST


This is all the information about APD 2320025848. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2320025848
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A09
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.8 V
Dark current: 5.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 4
Position in Box: 34
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 21. Sep 2018
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.790698 V     T = -25 °C: 351.2059609 V
Voltage for Gain 150: T = +20 °C: 394.6813583 V     T = -25 °C: 358.6825987 V
Voltage for Gain 200: T = +20 °C: 399.045013 V     T = -25 °C: 362.8579552 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.674068426 V-1     T = -25 °C: 4.826622719 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.362980965 V-1     T = -25 °C: 9.792944693 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.64856914 V-1     T = -25 °C: 15.62527768 V-1
Break-through voltage: T = +20 °C: 413.7251741 V     T = -25 °C: 377.5926989 V
   
Notes:


Version history

Time Author Change comment
15. Nov 2022 13:15:50 CET oafedulidis Assigned to capsule by script
16. Dec 2021 13:42:48 CET oafedulidis Updated box and position via API.
05. Feb 2021 10:48:05 CET jreher Updated box and position via API.
03. Feb 2021 18:14:25 CET jreher Updated box and position via API.
11. Aug 2020 17:20:26 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:30:04 CET jreher Updated APD location via API.
25. Nov 2019 17:11:13 CET jreher Updated box and position via API.
04. Jul 2019 11:05:22 CEST jreher Updated APD location via API.
04. Jul 2019 10:44:23 CEST jreher Updated APD location via API.
12. Jun 2019 16:45:42 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:30:38 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 15:00:01 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 00:12:39 CET Tobias Corrected dark current unit.
26. Sep 2018 11:20:51 CEST markus.moritz
12. Jan 2018 13:16:44 CET Tobias Imported from Hamamatsu datasheet.