Show Hamamatsu Avalanche Photo Diode 2519029024 - Archived data from Wed, 07. October 2020 12:16:40 CEST
This is all the information about APD 2519029024. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2519029024 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2519029024/2407026464 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | E13 |
Break-through voltage: | 410 V |
Voltage for Gain 100 (T=+25°C): | 381.4 V |
Dark current: | 4.2 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 67 |
Position in Box: | 42 |
EP1 batch: | 47 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 381.655496 V T = -25 °C: 345.9967079 V |
Voltage for Gain 150: | T = +20 °C: 389.4104197 V T = -25 °C: 353.3607583 V |
Voltage for Gain 200: | T = +20 °C: 393.7196172 V T = -25 °C: 357.5072738 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.460346296 V-1 T = -25 °C: 4.954244088 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.722494214 V-1 T = -25 °C: 9.133911773 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.21599452 V-1 T = -25 °C: 16.32439841 V-1 |
Break-through voltage: | T = +20 °C: 409.0406538 V T = -25 °C: 372.738074 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:57:01 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:22:34 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:16:40 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:50:15 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:33:36 CEST | jreher | Updated APD characteristics via API. |
20. Feb 2020 13:32:26 CET | jreher | Updated box and position via API. |
27. Nov 2019 19:40:40 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:14 CET | jreher | Updated box and position via API. |
05. Aug 2019 16:54:49 CEST | jreher | Updated APD batch assignment via API. |
29. Jul 2019 13:31:16 CEST | markus.moritz | |
05. Jul 2019 13:45:14 CEST | jreher | Updated APD location via API. |
01. Jul 2019 12:45:59 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:38 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:16 CET | Tobias | Imported from Hamamatsu datasheet. |