RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2519029016 - Archived data from Tue, 11. August 2020 17:33:34 CEST


This is all the information about APD 2519029016. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2519029016
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E01
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.5 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 67
Position in Box: 34
EP1 batch: 47
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.029005 V     T = -25 °C: 344.9941673 V
Voltage for Gain 150: T = +20 °C: 387.9439274 V     T = -25 °C: 352.4200937 V
Voltage for Gain 200: T = +20 °C: 392.3750642 V     T = -25 °C: 356.5934689 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.574839215 V-1     T = -25 °C: 4.917612365 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.917943854 V-1     T = -25 °C: 9.054776317 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.73497094 V-1     T = -25 °C: 15.98211344 V-1
Break-through voltage: T = +20 °C: 407.3522858 V     T = -25 °C: 371.1539501 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:57:00 CET jreher Updated box and position via API.
03. Feb 2021 18:22:33 CET jreher Updated box and position via API.
08. Dec 2020 17:10:58 CET jreher Assigned to capsule by script
06. Oct 2020 16:51:52 CEST jreher Updated box and position via API.
11. Aug 2020 17:33:34 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:39 CET jreher Updated APD location via API.
25. Nov 2019 17:16:13 CET jreher Updated box and position via API.
05. Aug 2019 16:54:42 CEST jreher Updated APD batch assignment via API.
29. Jul 2019 13:22:53 CEST markus.moritz
05. Jul 2019 13:45:13 CEST jreher Updated APD location via API.
01. Jul 2019 12:45:58 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:37 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:16 CET Tobias Imported from Hamamatsu datasheet.