RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2518028908 - Archived data from Wed, 03. February 2021 18:22:17 CET


This is all the information about APD 2518028908. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2518028908
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E10
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378 V
Dark current: 4.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 65
Position in Box: 30
EP1 batch: 43
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.9203967 V     T = -25 °C: 342.8752557 V
Voltage for Gain 150: T = +20 °C: 385.694486 V     T = -25 °C: 350.1827553 V
Voltage for Gain 200: T = +20 °C: 390.0259899 V     T = -25 °C: 354.2837087 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.686191742 V-1     T = -25 °C: 4.992793011 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.292191084 V-1     T = -25 °C: 9.386467414 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.53914049 V-1     T = -25 °C: 14.86276249 V-1
Break-through voltage: T = +20 °C: 405.8552401 V     T = -25 °C: 369.6079705 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:26:42 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:16:20 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:43 CET jreher Updated box and position via API.
03. Feb 2021 18:22:17 CET jreher Updated box and position via API.
11. Aug 2020 17:33:15 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:16 CET jreher Updated APD location via API.
25. Nov 2019 17:16:03 CET jreher Updated box and position via API.
05. Aug 2019 16:49:39 CEST jreher Updated APD batch assignment via API.
25. Jul 2019 15:27:21 CEST markus.moritz
05. Jul 2019 13:44:56 CEST jreher Updated APD location via API.
01. Jul 2019 13:08:19 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:34 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:14 CET Tobias Imported from Hamamatsu datasheet.