RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2517028888 - Archived data from Wed, 03. February 2021 18:22:16 CET


This is all the information about APD 2517028888. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2517028888
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2517028888/2003021672
Unit: #1368 (barcode 1309013982)
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: F14
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.8 V
Dark current: 3.7 nA
   
Screening Logistics:  
Available: No
Storage Box: 65
Position in Box: 19
EP1 batch: 43
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.3778683 V     T = -25 °C: 345.9571128 V
Voltage for Gain 150: T = +20 °C: 389.2272221 V     T = -25 °C: 353.3488425 V
Voltage for Gain 200: T = +20 °C: 393.6028631 V     T = -25 °C: 357.508524 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.516507706 V-1     T = -25 °C: 4.947447368 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.852219897 V-1     T = -25 °C: 9.258357734 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.56550999 V-1     T = -25 °C: 14.5680253 V-1
Break-through voltage: T = +20 °C: 409.288952 V     T = -25 °C: 372.9127524 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:56:42 CET jreher Updated box and position via API.
03. Feb 2021 18:22:16 CET jreher Updated box and position via API.
07. Oct 2020 12:16:33 CEST jreher Assigned to capsule by script
17. Aug 2020 15:50:15 CEST jreher Updated box and position via API.
11. Aug 2020 17:33:13 CEST jreher Updated APD characteristics via API.
20. Feb 2020 13:32:26 CET jreher Updated box and position via API.
27. Nov 2019 19:40:15 CET jreher Updated APD location via API.
25. Nov 2019 17:16:02 CET jreher Updated box and position via API.
05. Aug 2019 16:49:38 CEST jreher Updated APD batch assignment via API.
25. Jul 2019 15:19:11 CEST markus.moritz
05. Jul 2019 13:44:56 CEST jreher Updated APD location via API.
01. Jul 2019 13:08:18 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:34 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:13 CET Tobias Imported from Hamamatsu datasheet.