Show Hamamatsu Avalanche Photo Diode 2517028883 - Archived data from Tue, 11. August 2020 17:33:12 CEST
This is all the information about APD 2517028883. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2517028883 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B09 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 379.3 V |
Dark current: | 4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 65 |
Position in Box: | 14 |
EP1 batch: | 43 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 380.2422215 V T = -25 °C: 345.2336717 V |
Voltage for Gain 150: | T = +20 °C: 388.0522137 V T = -25 °C: 352.5871799 V |
Voltage for Gain 200: | T = +20 °C: 392.408184 V T = -25 °C: 356.6941416 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.537700276 V-1 T = -25 °C: 4.874643347 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.954328007 V-1 T = -25 °C: 10.00375078 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.90699621 V-1 T = -25 °C: 16.03392238 V-1 |
Break-through voltage: | T = +20 °C: 406.4530755 V T = -25 °C: 370.5491973 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:56:41 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:22:15 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:33:12 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:40:15 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:16:01 CET | jreher | Updated box and position via API. |
05. Aug 2019 16:48:27 CEST | jreher | Updated APD batch assignment via API. |
25. Jul 2019 15:15:37 CEST | markus.moritz | |
05. Jul 2019 13:44:55 CEST | jreher | Updated APD location via API. |
01. Jul 2019 13:08:18 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:34 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:13 CET | Tobias | Imported from Hamamatsu datasheet. |