Show Hamamatsu Avalanche Photo Diode 2517028830 - Archived data from Fri, 05. February 2021 10:56:34 CET


This is all the information about APD 2517028830. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2517028830
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D13
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 382.2 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 64
Position in Box: 12
EP1 batch: 41
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.3945192 V     T = -25 °C: 346.5519159 V
Voltage for Gain 150: T = +20 °C: 390.1312889 V     T = -25 °C: 353.9431326 V
Voltage for Gain 200: T = +20 °C: 394.4404754 V     T = -25 °C: 358.0792097 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.548896331 V-1     T = -25 °C: 4.722539857 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.012844561 V-1     T = -25 °C: 9.582104749 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.07125143 V-1     T = -25 °C: 15.2442795 V-1
Break-through voltage: T = +20 °C: 410.0645184 V     T = -25 °C: 373.4748949 V
   
Notes:


Version history

Time Author Change comment
18. May 2022 09:59:28 CEST oafedulidis Assigned to capsule by script
28. Apr 2021 13:28:24 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:34 CET jreher Updated box and position via API.
03. Feb 2021 18:22:07 CET jreher Updated box and position via API.
11. Aug 2020 17:33:02 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:40:04 CET jreher Updated APD location via API.
25. Nov 2019 17:15:57 CET jreher Updated box and position via API.
01. Aug 2019 12:11:14 CEST spankonin Updated APD batch assignment via API.
25. Jul 2019 12:00:04 CEST markus.moritz
05. Jul 2019 13:44:47 CEST jreher Updated APD location via API.
01. Jul 2019 14:30:52 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:32 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:12 CET Tobias Imported from Hamamatsu datasheet.