Show Hamamatsu Avalanche Photo Diode 2516028808 - Archived data from Mon, 25. November 2019 17:15:54 CET
This is all the information about APD 2516028808. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2516028808 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 63 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C11 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 378.2 V |
Dark current: | 5.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 63 |
Position in Box: | 45 |
EP1 batch: | 61 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 26. Aug 2019 |
Sent for analysis after irradiation: | 02. Sep 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Aug 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 31. Aug 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: | With Christopher Wenzel (Bochum) for test measurements. |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 15:12:31 CEST | oafedulidis | Assigned to capsule by script |
03. May 2021 15:20:24 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:56:30 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:22:03 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:45:25 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:39:55 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:54 CET | jreher | Updated box and position via API. |
11. Nov 2019 18:42:30 CET | spankonin | Updated APD batch assignment via API. |
04. Sep 2019 10:12:49 CEST | markus.moritz | |
08. Jul 2019 14:56:29 CEST | spankonin | Updated APD batch assignment via API. |
05. Jul 2019 13:44:42 CEST | jreher | Updated APD location via API. |
17. May 2019 14:05:52 CEST | jreher | |
03. Jan 2019 00:12:31 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:12 CET | Tobias | Imported from Hamamatsu datasheet. |