Show Hamamatsu Avalanche Photo Diode 2515028735 - Archived data from Thu, 03. January 2019 00:12:30 CET
This is all the information about APD 2515028735. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2515028735 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G12 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 387 V |
Dark current: | 5.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 62 |
Position in Box: | 43 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2021 10:34:22 CET | oafedulidis | Assigned to capsule by script |
16. Jun 2021 16:03:28 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:59:46 CEST | oafedulidis | Updated box and position via API. |
16. Jun 2021 15:52:26 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:56:22 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:56 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:32:50 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:39:44 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:49 CET | jreher | Updated box and position via API. |
01. Aug 2019 12:11:48 CEST | spankonin | Updated APD batch assignment via API. |
24. Jul 2019 14:17:38 CEST | markus.moritz | |
05. Jul 2019 13:44:33 CEST | jreher | Updated APD location via API. |
01. Jul 2019 14:30:04 CEST | spankonin | Updated APD batch assignment via API. |
03. Jan 2019 00:12:30 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:11 CET | Tobias | Imported from Hamamatsu datasheet. |