Show Hamamatsu Avalanche Photo Diode 2515028734 - Archived data from Tue, 11. August 2020 17:32:49 CEST


This is all the information about APD 2515028734. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2515028734
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D11
Break-through voltage: 412 V
Voltage for Gain 100 (T=+25°C): 383.1 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 62
Position in Box: 42
EP1 batch: 39
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 383.6170352 V     T = -25 °C: 347.8608034 V
Voltage for Gain 150: T = +20 °C: 391.4328841 V     T = -25 °C: 355.2223803 V
Voltage for Gain 200: T = +20 °C: 395.7740682 V     T = -25 °C: 359.3437006 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.495541722 V-1     T = -25 °C: 4.673247451 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.879898479 V-1     T = -25 °C: 9.50866317 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.71048526 V-1     T = -25 °C: 15.35894334 V-1
Break-through voltage: T = +20 °C: 410.8383968 V     T = -25 °C: 373.931688 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:56:22 CET jreher Updated box and position via API.
03. Feb 2021 18:21:55 CET jreher Updated box and position via API.
11. Aug 2020 17:32:49 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:44 CET jreher Updated APD location via API.
25. Nov 2019 17:15:48 CET jreher Updated box and position via API.
01. Aug 2019 12:11:48 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 14:17:02 CEST markus.moritz
05. Jul 2019 13:44:33 CEST jreher Updated APD location via API.
01. Jul 2019 14:30:03 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:30 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:11 CET Tobias Imported from Hamamatsu datasheet.