Show Hamamatsu Avalanche Photo Diode 2515028698 - Archived data from Wed, 03. February 2021 18:21:51 CET
This is all the information about APD 2515028698. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2515028698 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F12 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 384.5 V |
Dark current: | 5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 62 |
Position in Box: | 6 |
EP1 batch: | 38 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 17. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 384.3873941 V T = -25 °C: 348.6587404 V |
Voltage for Gain 150: | T = +20 °C: 392.1723863 V T = -25 °C: 356.0662376 V |
Voltage for Gain 200: | T = +20 °C: 396.493664 V T = -25 °C: 360.1927524 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.571652567 V-1 T = -25 °C: 4.668641469 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.118661393 V-1 T = -25 °C: 9.685609927 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.31715558 V-1 T = -25 °C: 15.4150995 V-1 |
Break-through voltage: | T = +20 °C: 411.3400877 V T = -25 °C: 375.2823556 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
10. Jun 2022 12:24:37 CEST | oafedulidis | Assigned to capsule by script |
27. Aug 2021 11:13:08 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:56:17 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:51 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:32:42 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:39:41 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:45 CET | jreher | Updated box and position via API. |
01. Aug 2019 12:12:49 CEST | spankonin | Updated APD batch assignment via API. |
24. Jul 2019 13:47:01 CEST | markus.moritz | |
05. Jul 2019 13:44:30 CEST | jreher | Updated APD location via API. |
01. Jul 2019 14:29:44 CEST | spankonin | Updated APD batch assignment via API. |
03. Jan 2019 00:12:28 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:10 CET | Tobias | Imported from Hamamatsu datasheet. |