Subdetector specification:  
Serial: 2515028697
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 411 V
Voltage for Gain 100 (T=+25°C): 383 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 62
Position in Box: 5
EP1 batch: 38
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 382.481004 V     T = -25 °C: 347.689079 V
Voltage for Gain 150: T = +20 °C: 390.3953172 V     T = -25 °C: 354.9982794 V
Voltage for Gain 200: T = +20 °C: 394.8013951 V     T = -25 °C: 359.0518512 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.473014275 V-1     T = -25 °C: 4.799270703 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.757416461 V-1     T = -25 °C: 9.883521426 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.4357167 V-1     T = -25 °C: 16.27979907 V-1
Break-through voltage: T = +20 °C: 410.4677878 V     T = -25 °C: 374.1992362 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:56:17 CET jreher Updated box and position via API.
03. Feb 2021 18:21:51 CET jreher Updated box and position via API.
11. Aug 2020 17:32:42 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:41 CET jreher Updated APD location via API.
25. Nov 2019 17:15:45 CET jreher Updated box and position via API.
01. Aug 2019 12:12:49 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 13:46:44 CEST markus.moritz
05. Jul 2019 13:44:30 CEST jreher Updated APD location via API.
01. Jul 2019 14:29:44 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:28 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:10 CET Tobias Imported from Hamamatsu datasheet.