RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2515028678 - Archived data from Mon, 03. May 2021 10:25:41 CEST


This is all the information about APD 2515028678. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2515028678
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G05
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 61
Position in Box: 26
EP1 batch: 37
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.3767934 V     T = -25 °C: 344.0585201 V
Voltage for Gain 150: T = +20 °C: 387.2098317 V     T = -25 °C: 351.4168127 V
Voltage for Gain 200: T = +20 °C: 391.5811819 V     T = -25 °C: 355.5485636 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.508401168 V-1     T = -25 °C: 4.94654464 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.979579603 V-1     T = -25 °C: 9.294635652 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.98734923 V-1     T = -25 °C: 14.79688581 V-1
Break-through voltage: T = +20 °C: 407.5829456 V     T = -25 °C: 371.1678481 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 09:59:29 CEST oafedulidis Assigned to capsule by script
10. May 2021 14:00:14 CEST oafedulidis Updated box and position via API.
03. May 2021 10:25:41 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:14 CET jreher Updated box and position via API.
03. Feb 2021 18:21:48 CET jreher Updated box and position via API.
11. Aug 2020 17:32:39 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:33 CET jreher Updated APD location via API.
25. Nov 2019 17:15:43 CET jreher Updated box and position via API.
01. Aug 2019 12:12:48 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 13:35:28 CEST markus.moritz
12. Jul 2019 13:55:40 CEST jreher Updated APD location via API.
01. Jul 2019 14:26:56 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:28 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:10 CET Tobias Imported from Hamamatsu datasheet.