RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2515028670 - Archived data from Fri, 05. February 2021 10:56:13 CET


This is all the information about APD 2515028670. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2515028670
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E04
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.2 V
Dark current: 4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 61
Position in Box: 20
EP1 batch: 37
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.2611292 V     T = -25 °C: 343.173063 V
Voltage for Gain 150: T = +20 °C: 386.0638455 V     T = -25 °C: 350.4432829 V
Voltage for Gain 200: T = +20 °C: 390.4178266 V     T = -25 °C: 354.5060411 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.594476407 V-1     T = -25 °C: 4.961223861 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.121322094 V-1     T = -25 °C: 9.405651684 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.30764812 V-1     T = -25 °C: 15.0907133 V-1
Break-through voltage: T = +20 °C: 406.8952086 V     T = -25 °C: 369.7202685 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:36:41 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:21:00 CEST oafedulidis Updated box and position via API.
03. May 2021 10:25:40 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:56:13 CET jreher Updated box and position via API.
03. Feb 2021 18:21:47 CET jreher Updated box and position via API.
11. Aug 2020 17:32:38 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:39:33 CET jreher Updated APD location via API.
25. Nov 2019 17:15:43 CET jreher Updated box and position via API.
01. Aug 2019 12:12:47 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 10:28:27 CEST markus.moritz
12. Jul 2019 13:55:40 CEST jreher Updated APD location via API.
01. Jul 2019 14:26:55 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:28 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:10 CET Tobias Imported from Hamamatsu datasheet.