Show Hamamatsu Avalanche Photo Diode 2514028627 - Archived data from Tue, 11. August 2020 17:32:31 CEST
This is all the information about APD 2514028627. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2514028627 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G11 |
Break-through voltage: | 405 V |
Voltage for Gain 100 (T=+25°C): | 377.5 V |
Dark current: | 6.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 61 |
Position in Box: | 4 |
EP1 batch: | 36 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 376.7886422 V T = -25 °C: 342.0705486 V |
Voltage for Gain 150: | T = +20 °C: 384.6040021 V T = -25 °C: 349.3278122 V |
Voltage for Gain 200: | T = +20 °C: 388.9734136 V T = -25 °C: 353.4052574 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.412787859 V-1 T = -25 °C: 5.150720915 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.719439786 V-1 T = -25 °C: 9.536666368 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.62545058 V-1 T = -25 °C: 15.75839839 V-1 |
Break-through voltage: | T = +20 °C: 404.3308039 V T = -25 °C: 368.4115781 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:56:10 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:21:43 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:17:44 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:50:47 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:32:31 CEST | jreher | Updated APD characteristics via API. |
20. Feb 2020 13:35:12 CET | jreher | Updated box and position via API. |
27. Nov 2019 19:39:30 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:15:40 CET | jreher | Updated box and position via API. |
01. Aug 2019 12:13:04 CEST | spankonin | Updated APD batch assignment via API. |
24. Jul 2019 10:02:48 CEST | markus.moritz | |
12. Jul 2019 13:55:37 CEST | jreher | Updated APD location via API. |
01. Jul 2019 14:24:50 CEST | spankonin | Updated APD batch assignment via API. |
03. Jan 2019 00:12:27 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:09 CET | Tobias | Imported from Hamamatsu datasheet. |