RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2514028623 - Archived data from Wed, 07. October 2020 12:17:15 CEST


This is all the information about APD 2514028623. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2514028623
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2514028623/0901009075
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: H08
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 381.1 V
Dark current: 8.6 nA
   
Screening Logistics:  
Available: No
Storage Box: 178
Position in Box: 50
EP1 batch: 36
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.6094547 V     T = -25 °C: 345.7172956 V
Voltage for Gain 150: T = +20 °C: 388.4863648 V     T = -25 °C: 353.07539 V
Voltage for Gain 200: T = +20 °C: 392.9010728 V     T = -25 °C: 357.1910939 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.522924292 V-1     T = -25 °C: 4.813221165 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.687845599 V-1     T = -25 °C: 9.766121551 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.74695348 V-1     T = -25 °C: 15.97135344 V-1
Break-through voltage: T = +20 °C: 407.9203297 V     T = -25 °C: 372.2971521 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:11:18 CET jreher Updated box and position via API.
07. Oct 2020 12:17:15 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:32 CEST jreher Updated box and position via API.
11. Aug 2020 17:32:30 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:29 CET jreher Updated APD location via API.
25. Nov 2019 17:24:56 CET jreher Updated box and position via API.
01. Aug 2019 12:13:04 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 10:01:14 CEST markus.moritz
05. Jul 2019 14:50:24 CEST jreher Updated APD location via API.
01. Jul 2019 14:24:50 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:27 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:09 CET Tobias Imported from Hamamatsu datasheet.