RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2514028586 - Archived data from Tue, 11. August 2020 17:32:23 CEST


This is all the information about APD 2514028586. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2514028586
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 380.4 V
Dark current: 8.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 178
Position in Box: 14
EP1 batch: 35
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.9500922 V     T = -25 °C: 344.9999526 V
Voltage for Gain 150: T = +20 °C: 387.7837997 V     T = -25 °C: 352.2797775 V
Voltage for Gain 200: T = +20 °C: 392.1298934 V     T = -25 °C: 356.3794087 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.813768385 V-1     T = -25 °C: 5.267655129 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.568527355 V-1     T = -25 °C: 9.656179902 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.23582864 V-1     T = -25 °C: 15.58833406 V-1
Break-through voltage: T = +20 °C: 407.8825844 V     T = -25 °C: 371.5163088 V
   
Notes:


Version history

Time Author Change comment
09. Feb 2021 11:21:02 CET jreher Assigned to capsule by script
05. Feb 2021 11:11:13 CET jreher Updated box and position via API.
18. Dec 2020 13:59:25 CET jreher Updated box and position via API.
11. Aug 2020 17:32:23 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:27 CET jreher Updated APD location via API.
25. Nov 2019 17:24:54 CET jreher Updated box and position via API.
30. Jul 2019 15:20:00 CEST spankonin Updated APD batch assignment via API.
24. Jul 2019 09:44:47 CEST markus.moritz
05. Jul 2019 14:50:22 CEST jreher Updated APD location via API.
01. Jul 2019 14:24:16 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:26 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:09 CET Tobias Imported from Hamamatsu datasheet.