RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2513028549 - Archived data from Fri, 05. February 2021 11:11:40 CET


This is all the information about APD 2513028549. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2513028549
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A11
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 389.2 V
Dark current: 6.2 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 181
Position in Box: 27
EP1 batch: 34
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 389.700965 V     T = -25 °C: 353.2097835 V
Voltage for Gain 150: T = +20 °C: 397.485347 V     T = -25 °C: 360.7344263 V
Voltage for Gain 200: T = +20 °C: 401.7931279 V     T = -25 °C: 364.9566562 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.463955095 V-1     T = -25 °C: 4.839867036 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.912625447 V-1     T = -25 °C: 8.869044952 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.14721735 V-1     T = -25 °C: 15.85147931 V-1
Break-through voltage: T = +20 °C: 416.5041823 V     T = -25 °C: 379.9050673 V
   
Notes:


Version history

Time Author Change comment
26. Oct 2021 10:45:59 CEST oafedulidis Assigned to capsule by script
17. May 2021 09:15:52 CEST oafedulidis Updated box and position via API.
21. Apr 2021 14:47:34 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:11:40 CET jreher Updated box and position via API.
11. Aug 2020 17:32:18 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:01:02 CET jreher Updated APD location via API.
25. Nov 2019 17:25:09 CET jreher Updated box and position via API.
30. Jul 2019 15:19:58 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 15:28:50 CEST jreher Updated APD batch assignment via API.
05. Jul 2019 14:50:48 CEST jreher Updated APD location via API.
24. Jun 2019 16:06:48 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:25 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:08 CET Tobias Imported from Hamamatsu datasheet.