RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2513028512 - Archived data from Tue, 11. August 2020 17:32:11 CEST


This is all the information about APD 2513028512. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2513028512
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C08
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 377.8 V
Dark current: 6.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 180
Position in Box: 50
EP1 batch: 33
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 377.6538427 V     T = -25 °C: 343.2769208 V
Voltage for Gain 150: T = +20 °C: 385.5348563 V     T = -25 °C: 350.5018665 V
Voltage for Gain 200: T = +20 °C: 389.9256116 V     T = -25 °C: 354.5394906 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.524771879 V-1     T = -25 °C: 5.056156301 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.786369553 V-1     T = -25 °C: 9.672413836 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.42456687 V-1     T = -25 °C: 15.54651876 V-1
Break-through voltage: T = +20 °C: 405.8129043 V     T = -25 °C: 369.4677638 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:36:39 CEST oafedulidis Assigned to capsule by script
03. May 2021 15:21:00 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:11:34 CET jreher Updated box and position via API.
11. Aug 2020 17:32:11 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:52 CET jreher Updated APD location via API.
25. Nov 2019 17:25:06 CET jreher Updated box and position via API.
30. Jul 2019 15:19:28 CEST spankonin Updated APD batch assignment via API.
05. Jul 2019 14:50:40 CEST jreher Updated APD location via API.
24. Jun 2019 16:09:54 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:24 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:08 CET Tobias Imported from Hamamatsu datasheet.