RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2512028460 - Archived data from Tue, 11. August 2020 17:32:05 CEST


This is all the information about APD 2512028460. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2512028460
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E12
Break-through voltage: 406 V
Voltage for Gain 100 (T=+25°C): 377 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 180
Position in Box: 18
EP1 batch: 32
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.9138512 V     T = -25 °C: 342.2119338 V
Voltage for Gain 150: T = +20 °C: 384.7364478 V     T = -25 °C: 349.4930528 V
Voltage for Gain 200: T = +20 °C: 389.0835763 V     T = -25 °C: 353.5832546 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.703301085 V-1     T = -25 °C: 4.951848784 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.570281898 V-1     T = -25 °C: 9.283796698 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.82730728 V-1     T = -25 °C: 14.94459471 V-1
Break-through voltage: T = +20 °C: 405.0652435 V     T = -25 °C: 368.9987928 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:11:30 CET jreher Updated box and position via API.
11. Aug 2020 17:32:05 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:49 CET jreher Updated APD location via API.
25. Nov 2019 17:25:03 CET jreher Updated box and position via API.
30. Jul 2019 15:19:13 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 10:59:55 CEST markus.moritz
05. Jul 2019 14:50:38 CEST jreher Updated APD location via API.
24. Jun 2019 16:13:10 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:22 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:07 CET Tobias Imported from Hamamatsu datasheet.