RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2512028439 - Archived data from Fri, 05. February 2021 11:11:25 CET


This is all the information about APD 2512028439. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2512028439
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 404 V
Voltage for Gain 100 (T=+25°C): 377.1 V
Dark current: 6.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 179
Position in Box: 49
EP1 batch: 31
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 376.9796335 V     T = -25 °C: 341.9227721 V
Voltage for Gain 150: T = +20 °C: 384.7648952 V     T = -25 °C: 349.1997902 V
Voltage for Gain 200: T = +20 °C: 389.0857082 V     T = -25 °C: 353.2821906 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.710630037 V-1     T = -25 °C: 5.052277209 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.402308196 V-1     T = -25 °C: 9.586862828 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.85771535 V-1     T = -25 °C: 15.41367444 V-1
Break-through voltage: T = +20 °C: 404.9878362 V     T = -25 °C: 368.7425923 V
   
Notes:


Version history

Time Author Change comment
16. Nov 2021 09:31:57 CET oafedulidis Assigned to capsule by script
17. May 2021 09:15:16 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:11:25 CET jreher Updated box and position via API.
11. Aug 2020 17:32:01 CEST jreher Updated APD characteristics via API.
27. Nov 2019 20:00:40 CET jreher Updated APD location via API.
25. Nov 2019 17:25:01 CET jreher Updated box and position via API.
30. Jul 2019 15:19:12 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 10:53:18 CEST markus.moritz
05. Jul 2019 14:50:32 CEST jreher Updated APD location via API.
24. Jun 2019 16:13:00 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:22 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:07 CET Tobias Imported from Hamamatsu datasheet.