RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2512028427 - Archived data from Tue, 11. August 2020 17:31:59 CEST


This is all the information about APD 2512028427. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2512028427
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2504027825/2512028427
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: red
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 407 V
Voltage for Gain 100 (T=+25°C): 378.5 V
Dark current: 6.8 nA
   
Screening Logistics:  
Available: No
Storage Box: 179
Position in Box: 38
EP1 batch: 31
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 378.1704297 V     T = -25 °C: 343.4144071 V
Voltage for Gain 150: T = +20 °C: 385.9950875 V     T = -25 °C: 350.6962733 V
Voltage for Gain 200: T = +20 °C: 390.3457876 V     T = -25 °C: 354.778463 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.60020915 V-1     T = -25 °C: 4.87704976 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.300373733 V-1     T = -25 °C: 9.267418722 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.83561002 V-1     T = -25 °C: 14.89721988 V-1
Break-through voltage: T = +20 °C: 406.3548377 V     T = -25 °C: 370.1856405 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:11:24 CET jreher Updated box and position via API.
11. Aug 2020 17:31:59 CEST jreher Updated APD characteristics via API.
03. Apr 2020 09:47:26 CEST jreher Assigned to capsule by script
20. Feb 2020 13:34:18 CET jreher Updated box and position via API.
27. Nov 2019 20:00:39 CET jreher Updated APD location via API.
25. Nov 2019 17:25:00 CET jreher Updated box and position via API.
30. Jul 2019 15:18:53 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 10:48:04 CEST markus.moritz
05. Jul 2019 14:50:32 CEST jreher Updated APD location via API.
24. Jun 2019 16:12:59 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:21 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:07 CET Tobias Imported from Hamamatsu datasheet.