Serial: | 2510028302 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F11 |
Break-through voltage: | 406 V |
Voltage for Gain 100 (T=+25°C): | 379.9 V |
Dark current: | 5.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 172 |
Position in Box: | 32 |
EP1 batch: | 27 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 379.8625545 V T = -25 °C: 344.8449938 V |
Voltage for Gain 150: | T = +20 °C: 387.7084078 V T = -25 °C: 352.1557777 V |
Voltage for Gain 200: | T = +20 °C: 392.0478199 V T = -25 °C: 356.2505126 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.716140539 V-1 T = -25 °C: 5.065915241 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.505286215 V-1 T = -25 °C: 9.622476303 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.91105942 V-1 T = -25 °C: 15.38753488 V-1 |
Break-through voltage: | T = +20 °C: 407.8674165 V T = -25 °C: 371.6591501 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:10:30 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:31:40 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:59:22 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:24:27 CET | jreher | Updated box and position via API. |
30. Jul 2019 15:17:57 CEST | spankonin | Updated APD batch assignment via API. |
23. Jul 2019 10:06:23 CEST | markus.moritz | |
05. Jul 2019 13:59:01 CEST | jreher | Updated APD location via API. |
24. Jun 2019 16:16:06 CEST | spankonin | Updated APD batch assignment via API. |
03. Jan 2019 00:12:18 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:05 CET | Tobias | Imported from Hamamatsu datasheet. |