RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2510028287 - Archived data from Tue, 11. August 2020 17:31:37 CEST


This is all the information about APD 2510028287. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2510028287
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.9 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 172
Position in Box: 17
EP1 batch: 27
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.4204758 V     T = -25 °C: 345.3799815 V
Voltage for Gain 150: T = +20 °C: 388.2219509 V     T = -25 °C: 352.6755448 V
Voltage for Gain 200: T = +20 °C: 392.554691 V     T = -25 °C: 356.7674241 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.603931457 V-1     T = -25 °C: 4.900913887 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.205452467 V-1     T = -25 °C: 9.361231034 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.41635911 V-1     T = -25 °C: 14.92138234 V-1
Break-through voltage: T = +20 °C: 407.4242664 V     T = -25 °C: 371.348679 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:28 CET jreher Updated box and position via API.
11. Aug 2020 17:31:37 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:21 CET jreher Updated APD location via API.
25. Nov 2019 17:24:26 CET jreher Updated box and position via API.
30. Jul 2019 15:17:45 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 10:00:15 CEST markus.moritz
05. Jul 2019 13:59:00 CEST jreher Updated APD location via API.
24. Jun 2019 16:16:05 CEST spankonin Updated APD batch assignment via API.
03. Jan 2019 00:12:17 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:05 CET Tobias Imported from Hamamatsu datasheet.