Show Hamamatsu Avalanche Photo Diode 2510028274 - Archived data from Tue, 11. August 2020 17:31:35 CEST
This is all the information about APD 2510028274. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2510028274 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 2810031549/2510028274 |
Unit: | #1034 (barcode 1309011247) |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | red |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 384.1 V |
Dark current: | 6.2 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 172 |
Position in Box: | 7 |
EP1 batch: | 26 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 384.405584 V T = -25 °C: 348.4761584 V |
Voltage for Gain 150: | T = +20 °C: 392.1754727 V T = -25 °C: 355.8980872 V |
Voltage for Gain 200: | T = +20 °C: 396.483586 V T = -25 °C: 360.0378302 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.697441024 V-1 T = -25 °C: 4.81281041 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.212238832 V-1 T = -25 °C: 8.979067437 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.73223114 V-1 T = -25 °C: 16.20631522 V-1 |
Break-through voltage: | T = +20 °C: 411.6032686 V T = -25 °C: 375.3418479 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:10:27 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:31:35 CEST | jreher | Updated APD characteristics via API. |
03. Apr 2020 09:45:24 CEST | jreher | Assigned to capsule by script |
13. Feb 2020 14:23:21 CET | jreher | Updated box and position via API. |
27. Nov 2019 19:59:20 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:24:25 CET | jreher | Updated box and position via API. |
30. Jul 2019 15:17:44 CEST | spankonin | Updated APD batch assignment via API. |
23. Jul 2019 09:53:44 CEST | markus.moritz | |
05. Jul 2019 13:58:59 CEST | jreher | Updated APD location via API. |
24. Jun 2019 14:50:26 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:17 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:04 CET | Tobias | Imported from Hamamatsu datasheet. |