Show Hamamatsu Avalanche Photo Diode 2510028262 - Archived data from Tue, 11. August 2020 17:31:34 CEST
This is all the information about APD 2510028262. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 2510028262 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B06 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 383.2 V |
Dark current: | 6.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 171 |
Position in Box: | 28 |
EP1 batch: | 26 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | 16. Jul 2019 |
Sent for analysis after irradiation: | 19. Jul 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Jul 2019 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 17. Jul 2019 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 383.2748357 V T = -25 °C: 348.6565087 V |
Voltage for Gain 150: | T = +20 °C: 391.1311589 V T = -25 °C: 355.9272068 V |
Voltage for Gain 200: | T = +20 °C: 395.4909495 V T = -25 °C: 359.9811684 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.603055105 V-1 T = -25 °C: 4.859613406 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.110165075 V-1 T = -25 °C: 10.11926802 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.50524315 V-1 T = -25 °C: 16.60721868 V-1 |
Break-through voltage: | T = +20 °C: 408.020401 V T = -25 °C: 375.0149139 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
03. May 2021 10:25:23 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:10:24 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:31:34 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:59:12 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:24:24 CET | jreher | Updated box and position via API. |
30. Jul 2019 15:17:44 CEST | spankonin | Updated APD batch assignment via API. |
23. Jul 2019 09:50:18 CEST | markus.moritz | |
05. Jul 2019 13:58:53 CEST | jreher | Updated APD location via API. |
24. Jun 2019 14:50:25 CEST | jgrochowski | Updated APD batch assignment via API. |
03. Jan 2019 00:12:17 CET | Tobias | Corrected dark current unit. |
12. Jan 2018 13:12:04 CET | Tobias | Imported from Hamamatsu datasheet. |