RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2509028234 - Archived data from Tue, 11. August 2020 17:31:31 CEST


This is all the information about APD 2509028234. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2509028234
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 2509028234/2501027638
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.3 V
Dark current: 7.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 171
Position in Box: 32
EP1 batch: 26
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 379.6242674 V     T = -25 °C: 344.5220881 V
Voltage for Gain 150: T = +20 °C: 387.4722148 V     T = -25 °C: 351.9087543 V
Voltage for Gain 200: T = +20 °C: 391.8537082 V     T = -25 °C: 356.0403161 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.485461726 V-1     T = -25 °C: 4.75581184 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.70622889 V-1     T = -25 °C: 9.845937502 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.23812572 V-1     T = -25 °C: 15.65958742 V-1
Break-through voltage: T = +20 °C: 407.9148636 V     T = -25 °C: 371.5799894 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:22 CET jreher Updated box and position via API.
11. Aug 2020 17:31:31 CEST jreher Updated APD characteristics via API.
31. Mar 2020 08:52:22 CEST jreher Assigned to capsule by script
13. Feb 2020 13:37:23 CET jreher Updated box and position via API.
27. Nov 2019 19:59:11 CET jreher Updated APD location via API.
25. Nov 2019 17:24:22 CET jreher Updated box and position via API.
30. Jul 2019 15:17:30 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 09:42:28 CEST markus.moritz
05. Jul 2019 13:58:52 CEST jreher Updated APD location via API.
24. Jun 2019 14:50:24 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:16 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:04 CET Tobias Imported from Hamamatsu datasheet.