RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2509028203 - Archived data from Tue, 11. August 2020 17:31:25 CEST


This is all the information about APD 2509028203. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2509028203
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 6.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 171
Position in Box: 1
EP1 batch: 25
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.596502 V     T = -25 °C: 350.9631692 V
Voltage for Gain 150: T = +20 °C: 393.5962569 V     T = -25 °C: 358.3316719 V
Voltage for Gain 200: T = +20 °C: 398.0469807 V     T = -25 °C: 362.4503551 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.438958447 V-1     T = -25 °C: 5.140410403 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.62809981 V-1     T = -25 °C: 9.51570444 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.19255507 V-1     T = -25 °C: 15.51331237 V-1
Break-through voltage: T = +20 °C: 413.0443348 V     T = -25 °C: 376.8440827 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:31:09 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:14:28 CEST oafedulidis Updated box and position via API.
03. May 2021 10:25:20 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:19 CET jreher Updated box and position via API.
11. Aug 2020 17:31:25 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:59:08 CET jreher Updated APD location via API.
25. Nov 2019 17:24:20 CET jreher Updated box and position via API.
30. Jul 2019 15:17:17 CEST spankonin Updated APD batch assignment via API.
23. Jul 2019 09:28:52 CEST markus.moritz
05. Jul 2019 13:58:50 CEST jreher Updated APD location via API.
24. Jun 2019 14:47:01 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:15 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:03 CET Tobias Imported from Hamamatsu datasheet.