RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2509028176 - Archived data from Tue, 11. August 2020 17:31:20 CEST


This is all the information about APD 2509028176. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2509028176
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D14
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 7.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 170
Position in Box: 27
EP1 batch: 24
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 386.5769076 V     T = -25 °C: 351.2244641 V
Voltage for Gain 150: T = +20 °C: 394.4405384 V     T = -25 °C: 358.622455 V
Voltage for Gain 200: T = +20 °C: 398.8143009 V     T = -25 °C: 362.7628115 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.497661778 V-1     T = -25 °C: 4.92077503 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.957047707 V-1     T = -25 °C: 9.240071275 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.95288218 V-1     T = -25 °C: 14.765599 V-1
Break-through voltage: T = +20 °C: 414.433685 V     T = -25 °C: 378.0830845 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:14 CET jreher Updated box and position via API.
11. Aug 2020 17:31:20 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:59 CET jreher Updated APD location via API.
25. Nov 2019 17:24:17 CET jreher Updated box and position via API.
30. Jul 2019 15:17:15 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 12:17:39 CEST markus.moritz
05. Jul 2019 13:58:44 CEST jreher Updated APD location via API.
24. Jun 2019 14:01:29 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:14 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:03 CET Tobias Imported from Hamamatsu datasheet.