RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 2508028153 - Archived data from Tue, 11. August 2020 17:31:17 CEST


This is all the information about APD 2508028153. If it is wrong, edit the data.

Subdetector specification:  
Serial: 2508028153
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C12
Break-through voltage: 408 V
Voltage for Gain 100 (T=+25°C): 379.7 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 170
Position in Box: 8
EP1 batch: 23
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 380.1453785 V     T = -25 °C: 344.7556797 V
Voltage for Gain 150: T = +20 °C: 387.9192929 V     T = -25 °C: 352.088807 V
Voltage for Gain 200: T = +20 °C: 392.248092 V     T = -25 °C: 356.2029283 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.657946171 V-1     T = -25 °C: 4.736819476 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.286907136 V-1     T = -25 °C: 9.627356294 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.59910307 V-1     T = -25 °C: 15.41014903 V-1
Break-through voltage: T = +20 °C: 408.078806 V     T = -25 °C: 371.7285589 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:10:12 CET jreher Updated box and position via API.
11. Aug 2020 17:31:17 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:58 CET jreher Updated APD location via API.
25. Nov 2019 17:24:16 CET jreher Updated box and position via API.
30. Jul 2019 15:16:40 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 17:09:45 CEST markus.moritz
05. Jul 2019 13:58:43 CEST jreher Updated APD location via API.
24. Jun 2019 13:56:26 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:14 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:03 CET Tobias Imported from Hamamatsu datasheet.