Serial: 2508028138
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C07
Break-through voltage: 410 V
Voltage for Gain 100 (T=+25°C): 381.1 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 169
Position in Box: 28
EP1 batch: 23
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: 16. Jul 2019
Sent for analysis after irradiation: 19. Jul 2019
Return for assembly: none
   
Irradiation:  
Date: 16. Jul 2019
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 17. Jul 2019
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.2718811 V     T = -25 °C: 346.2487091 V
Voltage for Gain 150: T = +20 °C: 389.1168066 V     T = -25 °C: 353.6015333 V
Voltage for Gain 200: T = +20 °C: 393.4793523 V     T = -25 °C: 357.7193317 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.496485434 V-1     T = -25 °C: 4.890311368 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.154244385 V-1     T = -25 °C: 9.30708193 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.52637514 V-1     T = -25 °C: 14.87400528 V-1
Break-through voltage: T = +20 °C: 409.4427268 V     T = -25 °C: 373.086391 V
   
Notes:


Version history

Time Author Change comment
26. Apr 2021 14:28:33 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:10:08 CET jreher Updated box and position via API.
11. Aug 2020 17:31:15 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:58:49 CET jreher Updated APD location via API.
25. Nov 2019 17:24:14 CET jreher Updated box and position via API.
30. Jul 2019 15:16:05 CEST spankonin Updated APD batch assignment via API.
19. Jul 2019 09:55:10 CEST markus.moritz
05. Jul 2019 13:58:37 CEST jreher Updated APD location via API.
24. Jun 2019 13:56:24 CEST jgrochowski Updated APD batch assignment via API.
03. Jan 2019 00:12:13 CET Tobias Corrected dark current unit.
12. Jan 2018 13:12:02 CET Tobias Imported from Hamamatsu datasheet.